flightchecklist.appFocus mode active
Beechcraft King Air C90B (Laminar) Emergency Procedures
Immediate Action Procedures
Tap a procedure to open its steps. Search covers step text, not just titles.
6 procedures
- 1If ITT rise predicts an over-temperature, or N1 stops accelerating normally:
- 2Condition LeverFUEL CUTOFF
- 3Ignition and Engine StartSTARTER ONLY (for remainder of starter time limit)
- 4Ignition and Engine StartOFF
- 5Do not attempt another start until the cause has been corrected
- 1Landing GearUP
- 2FlapsUP
- 3Confirm restart procedures for both engines are ineffective before feathering the second propeller
- 4PropellersFEATHERED
- 5Airspeed125 KNOTS
- 6Glide Ratio - 1.8 NM PER 1,000 FT (decrease 0.2 NM per 10 kt of headwind)
- 1PowerMAX ALLOWABLE
- 2Airspeed101 KNOTS
- 3FlapsUP
- 4Landing GearUP
- 5Airspeed (when clear of obstacles)NORMAL CLIMB
- 1GeneratorRESET, THEN ON
- 2If the generator will not reset:
- 3GeneratorOFF
- 4Operating GeneratorDO NOT EXCEED 100% LOAD
- 1Other InverterSELECT
- 2Voltage / FrequencyCHECK (105-120 V, 380-480 Hz)
- 1Maintain pitch control with elevator
- 2Control Wheel Trim SwitchTRIM OPPOSITE TO THE RUNAWAY
- 3Elevator Trim Switch (Pedestal)OFF
- 4Manual TrimRETRIM AS REQUIRED
- 5Do not reactivate electric trim until the cause has been determined
FLIGHT2.27.0Checklist
Beechcraft King Air C90B (Laminar)X-PLANE 12 · Emergency Procedures · 6procedures · 27 steps
Hot Start or Hung Start - On the Ground5 steps
| 01 | If ITT rise predicts an over-temperature, or N1 stops accelerating normally: | |
| 02 | Condition LeverFUEL CUTOFF | |
| 03 | Ignition and Engine StartSTARTER ONLY (for remainder of starter time limit) | |
| 04 | Ignition and Engine StartOFF | |
| 05 | Do not attempt another start until the cause has been corrected |
Glide - Both Engines Inoperative6 steps
| 01 | Landing GearUP | |
| 02 | FlapsUP | |
| 03 | Confirm restart procedures for both engines are ineffective before feathering the second propeller | |
| 04 | PropellersFEATHERED | |
| 05 | Airspeed125 KNOTS | |
| 06 | Glide Ratio - 1.8 NM PER 1,000 FT (decrease 0.2 NM per 10 kt of headwind) |
Balked Landing - Go-Around5 steps
| 01 | PowerMAX ALLOWABLE | |
| 02 | Airspeed101 KNOTS | |
| 03 | FlapsUP | |
| 04 | Landing GearUP | |
| 05 | Airspeed (when clear of obstacles)NORMAL CLIMB |
Generator Inoperative - L DC GEN or R DC GEN4 steps
| 01 | GeneratorRESET, THEN ON | |
| 02 | If the generator will not reset: | |
| 03 | GeneratorOFF | |
| 04 | Operating GeneratorDO NOT EXCEED 100% LOAD |
Inverter Inoperative - INVERTER Annunciator2 steps
| 01 | Other InverterSELECT | |
| 02 | Voltage / FrequencyCHECK (105-120 V, 380-480 Hz) |
Electric Elevator Trim - Unscheduled5 steps
| 01 | Maintain pitch control with elevator | |
| 02 | Control Wheel Trim SwitchTRIM OPPOSITE TO THE RUNAWAY | |
| 03 | Elevator Trim Switch (Pedestal)OFF | |
| 04 | Manual TrimRETRIM AS REQUIRED | |
| 05 | Do not reactivate electric trim until the cause has been determined |