- 1LH / RH ENGINE FIRE AnnunciatorIDENTIFY the illuminated (affected) engine
- 2Guard (affected engine)LIFT
- 3ENGINE FIRE Annunciator Button (affected engine)PUSH to extinguish
- 4The engine cannot be restarted after this action
- 1UNLOCK / DEPLOY Lights (Thrust Reverser Control Panel)CHECK affected side
- 2STOW EMER Switch (affected side)ACTIVATE to force the bucket to stowed
- 1LOAD SHED O'RIDE SwitchO'RIDE to keep the PFD, MFD and EICAS powered
- 2Without override, the displays turn off to save the batteries
- 3STBY PWR Switch - ON if the generators fail in flight (powers the standby instruments)
FLIGHT2.27.0Checklist
Cessna Citation X (Laminar)X-PLANE 12 · Emergency Procedures · 3procedures · 9 steps
Engine Fire (X-Plane Manual System Actions)4 steps
| 01 | LH / RH ENGINE FIRE AnnunciatorIDENTIFY the illuminated (affected) engine | |
| 02 | Guard (affected engine)LIFT | |
| 03 | ENGINE FIRE Annunciator Button (affected engine)PUSH to extinguish | |
| 04 | The engine cannot be restarted after this action |
Thrust Reverser Unwanted Deployment (X-Plane Manual System Actions)2 steps
| 01 | UNLOCK / DEPLOY Lights (Thrust Reverser Control Panel)CHECK affected side | |
| 02 | STOW EMER Switch (affected side)ACTIVATE to force the bucket to stowed |
Generator Failure (X-Plane Manual System Actions)3 steps
| 01 | LOAD SHED O'RIDE SwitchO'RIDE to keep the PFD, MFD and EICAS powered | |
| 02 | Without override, the displays turn off to save the batteries | |
| 03 | STBY PWR Switch - ON if the generators fail in flight (powers the standby instruments) |