flightchecklist.appFocus mode active
DCS WORLD · Fighter
F-16C Viper Emergency Procedures
Immediate Action Procedures
Tap a procedure to open its steps. Search covers step text, not just titles.
6 procedures
- 1ThrottleOFF
- 2Main fuel shutoffOFF
- 3Fire lightCONFIRM
- 4If controllableattempt restart above 15,000 ft
- 5If uncontrollableEJECT
- 6Minimum eject altitude2,000 ft AGL
- 1Airspeed250 KIAS
- 2JFSSTART
- 3ThrottleOFF then advance to IDLE
- 4Monitor RPMshould rise above 55%
- 5EPUverify AUTO (emergency power)
- 6If no relight below 10,000 ftEJECT
- 1Ejection handlePULL
- 2ACES II seatzero-zero capable
- 3If time permitsorient into wind
- 4If time permitsSquawk 7700, MAYDAY
- 5Uncontrolled below 6,000 ft AGLEJECT IMMEDIATELY
- 1HYD A / HYD BCHECK
- 2If single systemreduced maneuvering
- 3Manual TF / GCASDISABLED
- 4If dual failureEJECT (no flight control)
- 5Land immediately if single-system failure
- 1EPU lightCHECK ON
- 2Hydrazine fuel10 min max duration
- 3Land immediatelynearest suitable runway
- 4Do not shut down EPU in flight
- 5After landingnotify ground crew (hazmat)
- 1ALT REL buttonPRESS (selective)
- 2Or EMERG STORES JETTPRESS (all stations)
- 3Confirm stores released
- 4Master ArmSAFE
- 5Notify ATC of jettison location
FLIGHT2.22.0Checklist
F-16C ViperDCS WORLD · Emergency Procedures · 6procedures · 32 steps
Engine Fire / Overheat6 steps
| 01 | ThrottleOFF | |
| 02 | Main fuel shutoffOFF | |
| 03 | Fire lightCONFIRM | |
| 04 | If controllableattempt restart above 15,000 ft | |
| 05 | If uncontrollableEJECT | |
| 06 | Minimum eject altitude2,000 ft AGL |
Engine Flameout6 steps
| 01 | Airspeed250 KIAS | |
| 02 | JFSSTART | |
| 03 | ThrottleOFF then advance to IDLE | |
| 04 | Monitor RPMshould rise above 55% | |
| 05 | EPUverify AUTO (emergency power) | |
| 06 | If no relight below 10,000 ftEJECT |
Ejection5 steps
| 01 | Ejection handlePULL | |
| 02 | ACES II seatzero-zero capable | |
| 03 | If time permitsorient into wind | |
| 04 | If time permitsSquawk 7700, MAYDAY | |
| 05 | Uncontrolled below 6,000 ft AGLEJECT IMMEDIATELY |
Hydraulic Failure5 steps
| 01 | HYD A / HYD BCHECK | |
| 02 | If single systemreduced maneuvering | |
| 03 | Manual TF / GCASDISABLED | |
| 04 | If dual failureEJECT (no flight control) | |
| 05 | Land immediately if single-system failure |
EPU Activation5 steps
| 01 | EPU lightCHECK ON | |
| 02 | Hydrazine fuel10 min max duration | |
| 03 | Land immediatelynearest suitable runway | |
| 04 | Do not shut down EPU in flight | |
| 05 | After landingnotify ground crew (hazmat) |
Jettison Stores5 steps
| 01 | ALT REL buttonPRESS (selective) | |
| 02 | Or EMERG STORES JETTPRESS (all stations) | |
| 03 | Confirm stores released | |
| 04 | Master ArmSAFE | |
| 05 | Notify ATC of jettison location |